MAS and SSFA Ease Data Centre Power Limits for Water-Saving Facilities Across Asia
MAS and the SSFA updated the Singapore-Asia Taxonomy with flexible PUE and WUE formulas so water-efficient data centres qualify for green financing.

By Jin, Founder & Startups
4 min read
The Singapore Sustainable Finance Association (SSFA), backed by the Monetary Authority of Singapore (MAS), has released the second edition of the Singapore-Asia Taxonomy for Sustainable Finance (SAT), introducing revised technical screening criteria for regional data centres.
Unveiled during COP31 in Antalya, Turkey, the updated framework addresses a long-standing engineering trade-off for AI and cloud data centres operating across water-stressed markets in Southeast Asia and wider Asia.
The PUE and WUE engineering trade-off
Data centre operators have historically been judged on Power Usage Effectiveness (PUE), which measures total facility energy divided by IT equipment energy. However, evaporative cooling towers that achieve low PUE consume millions of litres of fresh water per day.
When operators deploy closed-loop, air-cooled, or liquid-to-air heat rejection systems to cut Water Usage Effectiveness (WUE), mechanical chillers draw more electricity, raising PUE. Under rigid single-metric thresholds, water-saving facilities in arid or water-scarce regions risked losing eligibility for green and transition project finance.
Exact taxonomy formulas for regional facilities
While facilities located inside Singapore remain bound by the Building and Construction Authority and Infocomm Media Development Authority (BCA-IMDA) Green Mark standard, the revised SAT sets coupled PUE-WUE formulas for cross-border projects elsewhere in Asia.
For Green classification, new facilities must maintain an average annual PUE no higher than 1.40 minus (0.0545 multiplied by WUE), with WUE strictly capped at 2.2. For Amber (transition) classification covering existing data centres, operators must meet a PUE ceiling of 1.45 minus (0.04545 multiplied by WUE), with WUE capped at 2.3.
Under the Green formula, a facility operating at near-zero water use (WUE close to 0) is permitted a PUE up to 1.40, whereas a water-evaporative facility running at a WUE of 2.0 must hit a tighter PUE of roughly 1.29.
What it changes for APAC infrastructure capital
Singapore banks and regional infrastructure funds use the SAT to label green loans, sustainability-linked bonds, and transition credit facilities for hyperscale campuses in Johor, Batam, Indonesia, India, and Thailand. By codifying the water-power trade-off into bankable formulas, developers building high-density AI clusters can finance dry-cooling and closed-loop liquid systems without facing greenwashing disqualifications.
Frequently Asked Questions
Does this change data centre rules inside Singapore?
No. Data centres built within Singapore continue to follow the BCA-IMDA Green Mark framework. The coupled PUE-WUE formulas apply to regional projects outside Singapore financed under the Singapore-Asia Taxonomy.
What is the maximum WUE allowed under the Green tier?
The second edition of the Singapore-Asia Taxonomy caps Water Usage Effectiveness (WUE) at 2.2 for Green classification and 2.3 for Amber transition classification.
Why do water-saving data centres have higher PUE?
Dry-cooling and closed-loop chillers avoid evaporating municipal or ground water, but they require extra compressor and fan electricity, which raises the facility's PUE ratio.
Subscribe to the TechWhoKnows newsletter for daily Singapore, ASEAN, and global infrastructure coverage.
Sources